MODEL P8/P108 Differential or Absolute Pressure Transducer

The Tavis Model P8 transducer is ideally suited to applications requiring very low differential pressure measurements. Available in pressure ranges as low as 0.01 psid, this differential pressure transducer features lowpower consumption and zero and full scale adjustments. The all welded stainless steel construction and a stable electronics package combine to produce an extremely accurate, but rugged unit.


HIGH ACCURACY
LONG TERM STABILITY
STABLE CALIBRATION
ALL WELDED CONSTRUCTION
VERY LOW PRESSURE RANGES
 
GENERAL SPECIFICATIONS
Pressure Ranges
Proof Pressure
Line Pressure
Weight
Sensor Type
Media
 
0 to .01 through 0 to 350 psi
20 psid or 200% F.R. (Higher proof pressures available. Consult factory)
20 psia or 200% F.R. (Higher line pressures available. Consult factory)
3.5lbs max.
Variable reluctance
Liquids or gases compatible with 410 SS, 17-4 PH SS and Iconel
 
ELECTRICAL
Input Voltage
Input Current
Output
Output Impedance
Output Noise
Insulation Resistance
Isolation Resistance
 
20 to 40 VDC
10 mA max.
0 to 5 VDC
100 ohms max.
15 mV P-P max.
100 megohms min. at 100 VDC
100 megohms min. at 100 VDC
 
PERFORMANCE
Static Error Band *
Hysteresis
Repeatability
Temperature Error *
Frequency Response *
Regulation
Resolution
 
± 0.5% F.S. max. (2)
± 0.1% F.S. nom.
± 0.1% F.S. nom.
± 2.0% F.S. max. (2)
Flat ± 5% to 250 Hz
0.05% F.S. per volt max.
Infinite
 
ENVIRONMENTAL
Temperature Range:
Compensated
Operating
Vibration
Shock
Humidity, Altitude, Rain,
Fungus, Salt spray, Sand,
and Dust
 

- 65 F to + 165 F (2)
- 65 F to + 200 F
20 g s Peak to 2000 Hz
100 g s, 11 ms


Unaffected

*Static Error Band is defined as the maximum allowed deviation from a best fit straight line which minimizes errors due to the combined effects of nonlinearity, hysteresis, resolution, and non-repeatability.
 
*Temperature Error is defined as the maximum allowed deviation from a best fit straight line which minimizes errors due to temperature over the range of 65 F to + 165 F.
 
*Frequency Response given is for electronics only. Actual frequency response will depend on pressure range and media.

(1)
All Tavis transducers can be supplied for corrosive media applications.Materials used for this purpose are 17-4 PH SS, 17-7 PH SS and Iconel . Specify model P108 for this feature.
(2)
Closer tolerances and higher temperature operation may be supplied. Consult factory for special requirements.
(3)
This unit is also available in a two wire 4 to 20 mA configuration. Add C following model number for this feature

P1-P101

P1-P101-2

"Let us handle your pressure"