MODEL P4/P104 Differential or Absolute Pressure Transducer

TheModel P4 pressure transducer features adjustable zero and full scale. Utilizing all welded construction and extremely stable electronics, this transducer provides highly accurate pressuremeasurements in harsh environments. TheModel P4 is available in absolute and differential pressure models with input to output isolation.


HIGH ACCURACY
LONG TERM STABILITY
STABLE CALIBRATION
ALL WELDED CONSTRUCTION
 
GENERAL SPECIFICATIONS
Pressure Ranges
Proof Pressure
Line Pressure
Weight
Sensor Type
Media
 
0 to 0.1 through 0 to 350 psi
20 psi or 200% F.S. (Higher proof pressures available. Consult factory)
20 psia or 200% F.S. (Higher line pressures available. Consult factory)
16 oz. max.
Variable reluctance
Liquids or gases compatible with 410 SS, 17-4 PH SS and Iconel
 
ELECTRICAL
Input Voltage
Input Current
Output
Output Impedance
Output Noise
Insulation Resistance
Isolation Resistance
Adjustment Range:
Zero
Span
 
20 to 40 VDC
10 mA max.
0 to 5 VDC
100 ohms max.
15 mV P-P max.
100 megohms min. at 100 VDC
100 megohms min. at 100 VDC

± 2.0% F.S. min.
± 2.0% F.S. min.
 
PERFORMANCE
Static Error Band *
Hysteresis
Repeatability
Temperature Error *
Frequency Response *
Regulation
Resolution
 
± 0.5% F.S. max. (2)
± 0.1% F.S. nom.
± 0.1% F.S. nom.
± 2.0% F.S. max. (2)
Flat ± 5% to 250 Hz
0.05% F.S. per volt max.
Infinite
 
ENVIRONMENTAL
Temperature Range:
Compensated
Operating
Vibration
Shock
Humidity, Altitude, Rain,
Fungus, Salt spray, Sand,
and Dust
 

- 65 F to + 165 F (2)
- 65 F to + 200 F
20 g s Peak to 2000 Hz
100 g s, 11 ms


Unaffected

*Static Error Band is defined as the maximum allowed deviation from a best fit straight line which minimizes errors due to the combined effects of nonlinearity, hysteresis, resolution, and non-repeatability.
 
*Temperature Error is defined as the maximum allowed deviation from a best fit straight line which minimizes errors due to temperature over the range of 65 F to + 165 F.
 
*Frequency Response given is for electronics only. Actual frequency response will depend on pressure range and media.

(1)
All Tavis transducers can be supplied for corrosive media applications. Materials used for this purpose are 17-4PH SS, 17-7PH SS and Iconel . Specify model P104 for this feature.
(2)
Closer tolerances and higher temperature operation may be supplied. Consult factory for special requirements.
(3)
Add 0.5 inches to length for absolute units with ranges less than 5 psia.

P1-P101

P1-P101-2

 

 

"Let us handle your pressure"


©2008 Tavis Corporation. All rights reserved. | Site by K&N Web Design | Sitemap