MODEL P1/P101 Differential or Absolute Pressure Transducer

The Model P1 pressure transducer is designed for use in applications where size, weight, and power consumption are prime considerations. The combination of all stainless steel welded construction and an extremely stable electronic package results in a transducer ideally suited to tough environments.


HIGH ACCURACY
LONG TERM STABILITY
STABLE CALIBRATION
ALL WELDED CONSTRUCTION
SMALL SIZE
 
GENERAL SPECIFICATIONS
Pressure Ranges
Proof Pressure
Line Pressure
Weight
Sensor Type
Media
 
0 to 1 psi through 0 to 350 psi
20 psi or 200% F.S. (Higher proof pressures available. Consult factory)
20 psia or 200% F.S. (Higher line pressures available. Consult factory)
6 oz. max.
Variable reluctance
Liquids or gases compatible with 410 SS, 17-4PH SS and Iconel
 
ELECTRICAL
Input Voltage
Input Current
Output
Output Noise
Output Impedance
Insulation Resistance
Isolation Resistance
 
20 to 40 VDC
10mA max.
0 to 5 VDC
15mV P-P max.
100 ohm max.
100 megohms min. at 100 VDC
50 megohms min. at 100 VDC
 
PERFORMANCE
Static Error Band* Hysteresis
Repeatability
Temperature Error *
Frequency Response *
Regulation
Resolution
 
± 0.5% F.S. max. (2)
± 0.1% F.S. nom.
± 0.1% F.S. nom.
± 2.0% F.S. max. (2)
Flat ± 5% to 250 Hz
0.05% F.S. per volt max.
Infinite
 
ENVIRONMENTAL
Temperature Range:
Compensated
Operating
Vibration
Shock
Humidity, Altitude, Rain,
Fungus, Salt spray, Sand,
and Dust
 

- 65 F to + 165 F (2)
- 65 F to + 200 F
20 g s Peak to 2000 Hz
100 g s, 11 ms


Unaffected

*Static Error Band is defined as the maximum allowed deviation from a best fit straight line which minimizes errors due to the combined effects of non-linearity, hysteresis, resolution, and non-repeatability.
 
*Temperature Error is defined as the maximum allowed deviation from a best fit straight line which minimizes errors due to temperature over the range of — 65˚F to + 165˚F.
 
*Frequency Response given is for electronics only. Actual frequency response will depend on pressure range and media.

(1)
All Tavis transducers can be supplied for corrosive media applications. Materials used for this purpose are 17-4PH SS, 17-7PH SS and Iconel™. Specify model P101 for this feature.
(2)
Closer tolerances and higher temperature operation may be supplied. Consult factory for special requirements.
(3)
Add 0.5 inches to length for absolute units with ranges less than 5 psia.

P1-P101

P1-P101-2

 

 

"Let us handle your pressure"


©2008 Tavis Corporation. All rights reserved. | Site by K&N Web Design | Sitemap